High Efficiency

Full dc inverter technology

The DC inverter technology adopted for both the compressors and fans means that they precisely fulfil the load required by the system while ensuring efficiency, continuity of operation and a greater silence level.

    Additional exchanger for subcooling control

    Using a plate heat exchanger as a secondary intercooler can increase refrigerant subcooling by up to 15°C, thereby improving heat exchange and energy efficiency

      Minimal consumption in standby mode

      The optimised control system reduces power consumption during standby mode by up to 3.5 W

        60 steps of capacity limitation

        If the power supply is limited, the units can be controlled to provide between 40% and 100% of the capacity with a 1% discretisation step.


         

        Wide application range

        Wide operating range

        Functioning is ensured in a wide ambient temperature range. Units can operate stabily from -15°C up to 52°C in cooling mode and from -20°C to 30°C in heating mode

        Long piping length

        Total piping length is extended up to 300 m and maximum height difference between outdoor and indoor unts up to 50 m. The heigth difference between indoor units can be up to 15 m. These generous allowances facilitate an extensive array of system designs.

        Il miglior comfort

        Molteplici modalità di priorità di funzionamento disponibili

        La priorità della modalità di funzionamento può essere impostata in modo da soddisfare le specifiche esigenze dell'utente tra 10 diverse modalità. La preferenza può essere selezionata direttamente in campo

        Modalità silenziose

        Per l'attenuazione della potenza sonora sono disponibili 5 modalità silenziose che permettono di soddisfare qualsiasi esigenza specifica.

        High Reliability

        Anti-corrosion protection

        Outdoor units are given anti-corrosion treatment for non-extreme conditions as standard and can also be customized with heavy anticorrosion treatment on main components for surface protection against corrosive air, acid rain and saline air (for installations in coastal regions) to extend overall useful life. The integrity of the anti-corrosion treatment is ensured by subjecting major components and parts to salt mist testing, moisture and heating testing and light aging testing.

        SCHEDA ELETTRONICA RAFFREDDATA A REFRIGERANTE

        Refrigerant cooling pcb

        The MSAN8-X series uses refrigerant cooling technology to cool the electric control box. It decreases the average temperature of electrical control components by about 8 degrees, guaranteeing the stable and safe running of the control system.

        Easy installation and maintenance

        Static fan pressure up to 35 pa

        The fan can be set to ensure up to 35 Pa of available pressure. In this way, the outdoor unit can be installed in technical rooms or in areas where the correct natural air flow cannot be ensured, ducting the air exhaust from the unit to the outside. 

        Automatic refrigerant recovery

        Thanks to a specific setting, the recovery and storage of refrigerant can be set in the outdoor unit or in the indoor units, thereby facilitating technical intervention and maintenance times.

        Auto addressing

        Outdoor unit can distribute addresses to indoor units automatically. 
        Remote and wired controllers can be used to query or modify each indoor unit’s address.

        Smart Input / Output contacts

        Standard supplied, practical connectors are available on the unit's electrical board to allow operations on site with other equipment as required by the user.
        - Input: Two contacts available to choose between cooling/heating mode only and forced shutdown.
        - Output: One contact available to choose between operation status and alarm signal.

        Compact design and easy transport and installation

        The compact design and light weight of the units minimise the footprint, reducing the weight loaded
        on the surfaces and making transport easier. The units can also be transported by lifts or forklift trucks, hence reducing installation time.
        This makes the system particularly suitable for applications where the visual impact on architecture needs to be limited, such as on historic or prestigious buildings.

        Comfort


        Follow me
        Follow me
        Turbo
        Turbo
        Mute Operation
        Mute Operation
        Silent
        Silent
        Stepless Indoor Fan Speed
        Stepless Indoor Fan Speed
        12 Grades Indoor Fan Speeds
        12 Grades Indoor Fan Speeds
        Stepless Outdoor Fan Speed
        Stepless Outdoor Fan Speed
        7 grades Outdoor Fan Speeds
        7 grades Outdoor Fan Speeds
        5 grades Outdoor Fan Speeds
        5 grades Outdoor Fan Speeds
        10 grades Outdoor Fan Speeds
        10 grades Outdoor Fan Speeds
        6 grades Outdoor Fan Speeds
        6 grades Outdoor Fan Speeds
        Anti-cold Air Function
        Anti-cold Air Function
        Temperature Compensation
        Temperature Compensation
        Multidirectional airflow
        Multidirectional airflow
        360° Airflow Panel
        360° Airflow Panel
        High Air Outlet Temperature
        High Air Outlet Temperature
        Auto Swing
        Auto Swing
        Long-Distance Windblast
        Long-Distance Windblast
        Hot Water (Heat/DHW)
        Hot Water (Heat/DHW)
        Ultra-low ambient heating
        Ultra-low ambient heating
        180° louver
        180° louver
        Breeze away
        Breeze away
        Cascade
        Cascade
        Humidity management
        Humidity management
        Stepless control compressor
        Stepless control compressor

        Health


        High Density filter
        High Density filter
        Cold Catalyst filter
        Cold Catalyst filter
        Self-Cleaning
        Self-Cleaning
        Fresh Air
        Fresh Air
        Purification filter
        Purification filter
        i-clean
        i-clean
        Anti-legionella
        Anti-legionella

        Reliability


        Refrigerant Leakage Detect
        Refrigerant Leakage Detect
        Self-diagnosis function
        Self-diagnosis function
        Emergency Using
        Emergency Using
        Auto Defrosting
        Auto Defrosting
        Low Ambient Cooling
        Low Ambient Cooling
        Build-in Drain pump
        Build-in Drain pump
        Chasis Heating Belt
        Chasis Heating Belt
        Compressor Heating Belt
        Compressor Heating Belt
        Back-up electrical heater
        Back-up electrical heater
        Auxiliary heating source
        Auxiliary heating source
        Opposite fan rotation
        Opposite fan rotation

        Energy Saving


        1W Stand-by
        1W Stand-by
        Sleep mode
        Sleep mode
        Intelligent Eye Detector
        Intelligent Eye Detector
        Gear
        Gear
        ECO
        ECO
        Holiday away
        Holiday away

        Convenience


        Manual Swich Button
        Manual Swich Button
        Remote On/Off
        Remote On/Off
        Error Alarm Port
        Error Alarm Port
        Wired Control
        Wired Control
        Central Control Management
        Central Control Management
        BMS Management
        BMS Management
        Wi-Fi control
        Wi-Fi control
        MONO/MULTI Compatible
        MONO/MULTI Compatible
        Louver Position Memory Function
        Louver Position Memory Function
        Auto Restart
        Auto Restart
        2-way Draining
        2-way Draining
        Timer
        Timer
        Weekley Timer
        Weekley Timer
        0,5°C Temperature Regulation
        0,5°C Temperature Regulation
        Automatic correction of the connection errors
        Automatic correction of the connection errors
        Voice control compatible
        Voice control compatible
        Rotation and back-up
        Rotation and back-up