HUNTER LODGE KAMNIK SKOPJE NORTH MACEDONIA HOTEL

Skopje, North Macedonia
Hotel
VRF System
Year 2020

AIR CONDITIONING FOR HOTEL

HUNTER LODGE KAMNIK SKOPJE NORTH MACEDONIA HOTEL

In 2020 the hotel was refurbished to increase the energy efficiency of the system and renew its style.

Hotel Hunter’s Lodge “Kamnik” is located at the entrance in Skopje, only 15 minutes form the airport and 10 min by car the town center.  

Hotel Hunter’s Lodge “Kamnik” has 16 rooms, 5 deluxe suites, conference /meeting room and gym/fitness center with outdoor tennis court.
 

The challenge

The goal that the property wanted to achieve with the plant redevelopment of the hotel was to offer maximum comfort for hotel guests, while increasing energy efficiency and therefore savings in operating costs, optimizing the initial investment cost also.

The aesthetic result was also very important.

HUNTER'S LODGE KAMNIK air conditioning plant

The solution

For heating, cooling and domestic hot water production, a Clivet VRF heat recovery system with high temperature hydromodule was chosen.

The 3-pipe VRF system and DX VRF ducted, high wall, floor indoor units provide simultaneous heating and cooling to the building and reach the highest levels of efficiency with maximum comfort for guests, granting the right temperature all the year round to bedrooms, suites, restaurant and all the other areas. 

The high temperature 14kW hydromodule  with a second compressor produces domestic hot water with temperatures up to 80°C.

The VRF system is controlled by a central controller, which allows the owner to manage all indoor units from one point and keep consumptions under control. 

The results

The high efficiency Clivet VRF system has contributed to increase the energy efficiency of the hotel, reducing the management costs.

Initial investment was in line with the property expectations. 

Also design requests were satisfied thanks to the Italian high design of Clivet VRF units.

It is expected that ROI will be achieved in 4 years through lowering the energy consumption and attracting new guests with a new look and very high level of comfort.
 

Clivet units:
  • 3 MV6R-XMI Outdoor units
  • 22 CNT2-2-XMI Medium static pressure Duct Indoor units 
  • 3 DZDF4-2-XMI D71 VRF Standing floor indoor units
  • 2 GWMN-2-XMI D28 VRF Wall mounted indoor units
  • 26 WDC-120G/WK wired controller for VRF indoor unit
  • 1 CCM-180A/WS touchscreen 6.2" centralized controller with weekly schedule
  • 1 HWM-2-XMI 140 VRF High temperature hydronic module for MV6R-XMI heat recovery system
The team

Installation: ENERGO SISTEM DOO SKOPJE
Clivet Distributor: ENERGO SISTEM DOO SKOPJE